Introduction
So far, the chapters have shown how to use ARES Electrical. From this chapter on, the focus shifts to the configuration of the application, so that every new project already starts in your company’s standard.
A complete electrical project is not just schematics and layout. It also has documentation pages: the cover, with the customer and project data, the table of contents, with the list of all pages, and the symbol table, with the symbols used in the project (Chapter 1). In ARES Electrical, these pages are not drawn by hand. They are generated automatically from blocks, which fill in the pages on their own.
In this chapter, you will:
Get to know the Options window and the Electrical Settings;
Import and export the settings to standardize the company’s projects;
Change the language of the interface and of the library;
Create, edit and delete pages in the Page Settings Wizard;
Understand the properties, the location and the five blocks of a page;
Create, edit and delete Page Groups, using the page you created.
Cover, table of contents and symbol table groups with their pages in the Project Palette
Electrical Settings
The Electrical Settings bring together the rules that ARES Electrical follows throughout the project: how pages are created and numbered, how components are named, how wires and cables are drawn and identified, and how commands behave.
Defining these rules only once, and reusing them in all projects, is what ensures that the company’s documents always follow the same standard, regardless of who drew the project.
Opening the Electrical Settings
The Electrical Settings can be opened in three ways:
From the Ribbon
On the Ribbon, click the Manage tab.
Click Electrical Settings…
With the AECFG command
Type AECFG in the command window.
Press Enter.
From the Options window
Type OPTIONS in the command window and press Enter.
In the Options window, click the Electrical tab.
💡TIP: Command: AECFG
With any of the three methods, ARES Electrical opens the Options window. On the left are the settings tabs:
File Locations – folders where the application looks for and saves files, such as templates, fonts, plot styles and autosave.
System Options – general behavior of the application, such as display, opening and saving files, and the application language.
User Preferences – personal work preferences, such as units, right mouse button behavior and shortcuts.
Drawing Settings – settings of the current drawing, such as units, display and entity creation.
Drafting Styles (Y) – drawing precision tools, such as entity snaps, grid and tracking.
Plug-ins – applications and add-ons loaded in the application.
Profiles (O) – saved sets of settings that let you switch between work standards.
Electrical – the Electrical Settings of the project, the subject of this chapter.
📖INFO: Use the Search settings field, in the upper right corner of the window, to find an option by name without browsing the tabs.
Options window with the tabs on the left
Getting to Know the Electrical Settings
The Electrical tab is organized into seven categories. Each category brings together groups of options related to one part of the project. To see the options of a category:
In the Options – Electrical window, click the + icon next to the category.
Click the + icon next to the group you want.
ARES Electrical shows the options of the group, with the current value of each one.
Project
Brings together the general project settings, divided into five groups:
General – basic project settings.
Macros – settings of the macros used in the project.
Blocks – settings of the blocks used in the project.
Reference – settings of the references between the project pages.
Default List Templates – templates used by default when generating reports (Chapter 3).
Project category with its five groups
Pages
Defines how the project pages are created, numbered and organized. It is the most important category in this chapter, because it controls the documentation pages. It is divided into four groups:
General – behavior of the pages during work: Edit Properties on Page Creation, Update macros automatically, Zoom on page change, Lock page block editing and Group Order, which defines the order of the Page Groups in the Project Palette.
Page Number – numbering format: Number of Characters, which defines the minimum number of digits, and Page Numbers per Project, which defines whether numbering is continuous in the project or restarts in each Page Group.
Page Group Functions – indicates which Page Group fulfills each special function: Panel Layout, Single Line Diagram, Cover, Caption and Page List (table of contents).
Page List – defines how the table of contents is built: lines and columns per page, spacing, description separator, separation by Page Group and inclusion of the table of contents itself in the list.
Pages category with the General, Page Number, Page Group Functions and Page List groups
Components
Controls the behavior of components in the schematic, in three groups:
General – component naming and editing rules, such as Avoid duplicate Tags, Use Automatic Naming, Reuse Deleted Terminal Numbers, Edit Properties on Insertion and Change Circuit/Location on move.
Insert – how components are placed: quadrant and value of the Insertion Angle, Show Components without Layout and Use Scale per Page.
Cross-reference – appearance of the contact table shown below the coils: Table Type (for example, Vertical contacts), position, line height, contact drawing scale and Automatic table.
Components category
Wires
Controls the drawing, numbering and connection of wires:
Wire corner – shape of the wire bends (for example, 90 Degrees) and the corner length.
Wire crossing – how crossings are drawn (for example, Cross, Gap and Bump) and the length.
General – busbar distance, Automatic wire numbering, Automatic wire branching, Connect wires at end point, wire dot block, Show Wire Properties on Insertion and Smart Wire Branching.
Wire Insertion Snaps – precision points (snaps) active while drawing wires.
Wire number – block used as the wire marker, alignment of the number to the wire and automatic numbering.
Wire Connection Point Snaps – snaps active when connecting the wire to a component.
Wire number position – where the number appears on the wire (for example, Middle) and the perpendicular and parallel distances from the wire.
Wires category
Cables
Controls cable identification:
Cable number – block used as the cable marker and Automatic insertion of cable numbers.
Cable number position – where the number appears on the cable and the perpendicular and parallel distances.
Cables category
Commands
Controls the behavior of the ARES Electrical commands:
General – Command Repeat, Update macros in commands, Quick wire drawing and Addressing Link.
Export – format of the exported data, such as the Concatenation Order (for example, Tag + Connection) and the tag and connection separators.
Revision – attributes used for the revision, description and date of the project and pages (for example, REV, DESCREV and DATEREV).
Routing – distances between ducts and components, additional wire length and Compute Duct Occupation (Chapter 3).
Topographic – representation of the topographic diagram and connection blocks used in it.
Compiler – project check before generating lists, exporting or printing. For each check (overlapping components, unnamed components, duplicate names, unnumbered terminals and others), choose Warning to be alerted or Ignore to skip the check.
📖INFO: Check Run the compiler before generating lists so that ARES Electrical points out errors, such as unnamed components or unnumbered terminals, before generating the reports.
Commands category
User
Brings together the user settings:
Library – library settings, such as Library Language, which defines the library language. The language can be changed to the languages enabled by the user, such as English or Portuguese.
User category with the Library group and the Library Language option
Importing and Exporting the Settings
The Import… and Export… buttons let you save the Electrical Settings to a file and load them into another project. With them, the company defines the standard only once and distributes it to the whole team.
Exporting the settings
Open the Electrical Settings.
To the right of the category tree, click Export…
In the Export Electrical Settings window, choose the folder where the file will be saved, preferably a folder shared with the team.
In the Name field, type a name that identifies the standard, for example AE_CFG_2027.
Make sure the Type field is set to Settings transfer files (*.cfg).
Click Save.
📖INFO: Manage > Customization > Electrical Settings.
ARES Electrical saves all Electrical Settings in the selected .cfg file.
📖INFO: The .cfg file (Settings transfer file) is the file in which ARES Electrical stores the exported Electrical Settings. It brings together the options of the categories of the Electrical tab (Project, Pages, Components, Wires, Cables, Commands and User) and is used to take these settings from one project or computer to another. The file can be copied, sent by email or kept in a shared folder and, to apply the settings, simply import it into ARES Electrical.
Export… button in the Options – Electrical window
Export Electrical Settings window with the .cfg file type
Importing the settings
Open the Electrical Settings.
To the right of the category tree, click Import…
In the Import Electrical Settings window, browse to the folder of the settings file.
Select the .cfg file and click Open. The window shows only Electrical Settings Files, which makes it easier to find the right file.
Check the categories that were loaded, such as Pages and Components.
Click OK.
📖INFO: Manage > Customization > Electrical Settings.
ARES Electrical applies the imported settings to the current project.
📖INFO: Importing replaces the current project settings. Export the current settings before importing, in case you need to go back to them.
📖INFO: Saved projects can also be used as settings files. If the company already has a project with the desired settings, this .dwg file can be used instead of a .cfg file to create a new project with the same standard.
Import… button in the Options – Electrical window
Import Electrical Settings window
Application and Library Language
ARES Electrical lets you choose two languages independently:
Application language – language of the Ribbon, menus, palettes, windows and application messages.
Library language – language of the names and descriptions of the components and symbols in the ARES Electrical library.
This way, you can, for example, work with the interface in English and use the library in another language, according to the customer’s standard.
Changing the Application Language
Open the Electrical Settings.
In the Options – Electrical window, click the System Options tab.
Click the + icon next to General and then the + icon next to Application language.
In the Select language as field, choose the language: German, Spanish, English, Portuguese or System.
Click OK.
Application language option on the System Options tab of the Options window
📖INFO: Manage > Customization > Electrical Settings.
ARES Electrical now uses the selected language in the interface.
📖INFO: The System option makes ARES Electrical use the same language as the operating system.
Changing the Library Language
Open the Electrical Settings.
Click the + icon next to the User category and then the + icon next to Library.
In the Library Language field, choose the library language: Portuguese or English.
Click OK.
Library Language option in the User category of the Electrical Settings
📖INFO: Manage > Customization > Electrical Settings.
ARES Electrical now uses the selected language in the library.
📖INFO: By default, the ARES Electrical library is available in English and Portuguese. Other languages only appear in the list when they are enabled by the user.
Configuring the Pages
The pages and Page Groups of the project are created and configured in the Page Settings Wizard. The wizard guides the process in steps: first you define the page properties, then the location (the grid of lines and columns) and, finally, the drawings that make up the page, such as the sheet format and the title block.
In this topic, you will create a page, edit it and delete it. Then, in Configuring Page Groups, the page you created will be used in a new Page Group.
Opening the Page Settings Wizard
On the Ribbon, click the Manage tab.
In the Settings panel, click Page Groups…
Page Groups… button in the Settings panel of the Manage tab
ARES Electrical opens the Page Settings Wizard, with the following options:
Create a new page group – creates a new Page Group.
Edit an existing page group – changes the settings of a group that was already created.
Delete one or more page groups – removes groups that are no longer used.
Create a new page – creates a new page, which can be used in the Page Groups.
Edit an existing page – changes the settings of a page that was already created.
Delete one or more pages – removes pages that are no longer used.
To move forward and back between screens, use the Next > and < Back buttons. The Cancel button closes the wizard without saving the changes.
Start screen of the Page Settings Wizard
Creating a Page
A new page can be created in two ways:
Using default values – the page starts with the ARES Electrical default settings, and all steps must be filled in.
Copying properties from: – the page starts with the settings of an existing page, chosen from the list. You only need to adjust what is different.
In this example, the new page will be created by copying the properties of an existing page, which is faster and ensures that it follows the same standard as the others.
Open the Page Settings Wizard.
On the Page Settings Wizard screen, select Create a new page.
Click Next >.
On the New page screen, under How do you want to create the page?, select Copying properties from:.
In the Name list, select the page that will be used as the base, for example [IEC] EN A3.
Click Next >.
New page screen with the Copying properties from: option and the list of existing pages
Page Properties
The Page properties screen defines the identification and the type of the page. Each line has three columns: Property, Value and Help, which explains what the property is for.
Name – identification of the page. When copying properties, the name starts as Copy of followed by the name of the source page, for example Copy of [IEC] EN A3. Change it to a name that identifies the new page.
Page type – defines the function of the page in the group:
Default – regular page, used in the schematics and in the layout.
Cover – project cover page.
Index – project table of contents page.
Description property – name of the property that stores the page description, for example DESCRIPTION. This is the description that appears in the title block and in the table of contents.
To fill in the properties:
In the Name line, click the Value column and type the page name.
In the Page type line, open the list and choose Default, Cover or Index.
In the Description property line, check the property name, for example DESCRIPTION.
Click Next >.
ARES Electrical saves the properties and moves to the Page location screen.
Page properties screen with the name TREINAMENTO and the Page type and Description property lines
Page Location
The Page location screen defines how the positions of the page are identified. These positions are used in cross-references and wire addressing, to indicate at which point of which page a component is located or where a wire continues, such as 6/A9.
The Location type field has four options:
Fixed rows and columns – the page is divided into a grid of columns and rows with fixed labels, such as columns 1, 2, 3… and rows A, B, C…. This is the standard for IEC sheets.
Sequential – restart every page – the positions are numbered in sequence, starting from the same value on every page.
Sequential – continuous – the positions are numbered in sequence, continuing from one page to the next.
Sequential – static increment – the positions are numbered in sequence, with a fixed jump between the start of one page and the start of the next.
The sequential types are used on ANSI sheets, where each line of the page receives a reference number instead of a column and row combination.
Options of the Location type field
Fixed rows and columns
Use fixed labels and sizes for the columns and rows of the grid. The position is indicated by the combination of row and column, for example A9.
In Location type, choose Fixed rows and columns.
Page location screen with the Fixed rows and columns type
In Column Labels, type the column labels, for example 1, 2, 3…, or click … to define them.
In Column Width, type the width of each column.
In Row Labels, type the row labels, for example A, B, C…, or click … to define them.
In Row Height, type the height of each row.
Click Next >.
ARES Electrical now identifies the page positions by the grid of columns and rows.
📖INFO: The number of columns multiplied by the width, and the number of rows multiplied by the height, must match the usable area of the Sheet format. This way, the labels are aligned with the divisions drawn on the border.
📖INFO: The calculation of the row and column positions uses the drawing origin (0,0) as the reference point. Draw the Sheet format from this point, so that the drawn grid is aligned with the calculated positions.
Sequential – restart every page
The location attributes are numbered from the same value on each page. For example, with Start at equal to 1, all pages start at 1.
In Location type, choose Sequential – restart every page.
Sequential – restart on each page type
In Start at, type the first number of each page, for example 1.
Click Next >.
ARES Electrical numbers the positions of each page from the defined value.
Sequential – continuous
The location attributes are numbered continuously across the pages: the numbering of a page continues from where the previous page stopped. For example, with Start at equal to 1 and a sheet with 26 positions, page 1 goes from 1 to 26, and page 2 starts at 27.
In Location type, choose Sequential – continuous.
Sequential – continuous type
In Start at, type the first number of the first page, for example 1.
Click Next >.
ARES Electrical numbers the positions in sequence across all pages.
Sequential – static increment
The location attributes are numbered with a fixed increment between pages. The start of each page is calculated by adding the Increment to the start of the previous page. For example, with Start at equal to 1 and Increment equal to 26, page 1 starts at 1, page 2 at 27 and page 3 at 53.
In Location type, choose Sequential – static increment.
Sequential – static increment type
In Start at, type the first number of the first page, for example 1.
In Increment, type the jump between the start of one page and the next, for example 26.
Click Next >.
ARES Electrical numbers the positions of each page from the start calculated with the increment.
💡TIP: Use an increment equal to the number of positions on the sheet, such as 26, so that the numbering continues without gaps. Use a round value, such as 100, so that each page starts at an easy-to-identify number (1, 101, 201…).
⚠️WARNING: On ANSI sheets, the location attributes of the Sheet format must follow the LOCAL_NUM format, where NUM is the number of the position on the sheet, with two digits: LOCAL_01, LOCAL_02, LOCAL_03 and so on. These are the attributes that ARES Electrical numbers according to the chosen Location type. To check or change an attribute, edit the Sheet format (see The Five Blocks), double-click the attribute and check the Name field in the Edit BlockAttribute window.
LOCAL_01 to LOCAL_26 attributes in the ANSI Sheet format and the Edit BlockAttribute window for the LOCAL_01 attribute
The Five Blocks
The Page drawings screen defines the five blocks that make up the page: Sheet format, Group properties, Page properties, Page number and Page total. Together, they build the frame and the title block of each project page.
On the left of the screen is the list of blocks and, on the right, the preview of the selected block. Below the preview are the buttons to work with each block:
Import – replaces the selected block with another drawing.
Edit – opens the block for editing in the graphics area.
Advanced – opens a selection box to choose a block stored on the computer and shows which block is currently in use.
Remove – removes the block from the page.
📖INFO: The Advanced button works the same way in all ARES Electrical creation wizards. It lets you use a block stored on the computer and check which block is in use.
The blocks have attributes: text fields that ARES Electrical fills in automatically with project and page information, such as the customer name, the revision or the page number. In the drawing, each attribute appears with its name, for example CUSTOMER, REV1 or PAG.
Sheet format
The Sheet format is the frame of the page: the outer borders, the margin and the grid of columns and rows, such as 1 to 9 and A to F. The grid follows what was defined in Page Location and is used in cross-references and wire addressing.
Sheet format block on the Page drawings screen
To edit the sheet format:
In the list on the left, click Sheet format.
Click Edit.
In the graphics area, adjust the frame, the margins or the grid of columns and rows.
Save and close the editing to return to the wizard.
ARES Electrical now uses the new frame on all pages created with this configuration.
📖INFO: If you change the number or size of the columns and rows drawn on the frame, also adjust the labels, width and height in Page location, so that the grid and the references remain aligned.
Editing the Sheet format, with the frame and the grid highlighted
Group properties
The Group properties block is the part of the title block with the project data. These data are the same on all pages of the group:
DWG-NAME – drawing name.
PRJ-NAME – project name.
CUSTOMER – customer.
ENGINEER, DESIGNER, CHECKED and APPROVED – people responsible for the project, the drawing, the check and the approval.
DWG-NUMBER – drawing number.
NUM-PROJ – project number.
Group properties block on the Page drawings screen
To edit the Group properties block:
In the list on the left, click Group properties.
Click Edit.
In the graphics area, adjust the title block, such as the company logo, the lines or the position of the attributes.
To change an attribute, double-click it, adjust the fields in the Edit BlockAttribute window and click OK.
Save and close the editing to return to the wizard.
ARES Electrical now uses the new title block on all pages of the group.
💡TIP: Replace the YOUR LOGO HERE logo with your company logo. This way, all project pages already have the company’s visual identity.
📖INFO: The values of the Group properties attributes are filled in in the project Global Properties (Chapter 1). When you change a value in the Global Properties, it is updated on all pages at once.
Editing the Group properties block, with the project attributes highlighted
Page properties
The Page properties block is the part of the title block with the data of the page itself. These data change from page to page:
REV1 to REV4 – identification of the page revisions.
DESCREV1 to DESCREV4 – description of each revision.
DATEREV1 to DATEREV4 – date of each revision.
DESCRIPTION – page description, which also appears in the table of contents.
SCALE – page scale.
Page properties block on the Page drawings screen
To edit the Page properties block:
In the list on the left, click Page properties.
Click Edit.
In the graphics area, adjust the position or size of the revision, description and scale attributes.
To change an attribute, double-click it, adjust the fields in the Edit BlockAttribute window and click OK.
Save and close the editing to return to the wizard.
ARES Electrical now uses the new block on all pages created with this configuration.
📖INFO: The title block has space for four revisions, filled in page by page as the project changes. When a fifth revision is added, the oldest one is overwritten. This way, the revisions are updated on a “rolling” basis and the title block always shows the four most recent ones.
Editing the Page properties block, with the revisions and the description highlighted
Page number
The Page number block has the PAG attribute, which shows the page number in the PAGE field of the title block. The number is filled in automatically, according to the numbering defined in the Electrical Settings.
Page number block (PAG) on the Page drawings screen
To edit the Page number block:
In the list on the left, click Page number.
Click Edit.
In the graphics area, double-click the PAG attribute.
In the Edit BlockAttribute window, adjust the Caption or the Value, if necessary, and click OK.
Save and close the editing to return to the wizard.
ARES Electrical now shows the page number with the new settings.
Edit BlockAttribute window for the PAG attribute
Page total
The Page total block has the OUT_OF attribute, which shows the total number of project pages in the OF field of the title block. Together with the page number, it forms the indication PAGE: 2 OF: 8, that is, page 2 of 8.
Page total block (OUT_OF) on the Page drawings screen
To edit the Page total block:
In the list on the left, click Page total.
Click Edit.
In the graphics area, double-click the OUT_OF attribute.
In the Edit BlockAttribute window, adjust the Caption or the Value, if necessary, and click OK.
Save and close the editing to return to the wizard.
ARES Electrical now shows the page total with the new settings.
📖INFO: The page total is updated automatically whenever pages are added to or removed from the project.
Edit BlockAttribute window for the OUT_OF attribute
Completing the Page Creation
After defining the properties, the location and the blocks, the wizard shows the Review screen, with a summary of what will be done, for example: The page Copy of [IEC] EN A3 will be created.
On the Page drawings screen, click Next >.
On the Review screen, check the summary of the changes.
Review screen with the summary of the page that will be created
If you need to correct something, click < Back and adjust the screen you want.
Click Finish.
ARES Electrical creates the new page, which now appears in the wizard’s page list and can be used in a Page Group.
Editing a Page
A page that was already created can be changed at any time with the same wizard. The screens are the same as for creation (Page properties, Page location and Page drawings), and you only need to move forward to the screen you want to change.
In this example, we will edit the TREINAMENTO page, created earlier.
Open the Page Settings Wizard (Manage tab → Settings → Page Groups…).
On the Page Settings Wizard screen, select Edit an existing page.
Page Settings Wizard with the Edit an existing page option selected
Click Next >.
On the Page selection screen, find the page in the Name list and check the box next to it, for example TREINAMENTO.
Page selection screen with the TREINAMENTO page checked
Click Next >.
On the Page properties screen, change the Name, the Page type or the Description property, if necessary (see Page Properties).
Page properties screen of the TREINAMENTO page
Click Next > until you reach the screen you want to change, for example Page drawings.
Make the changes you want. On Page drawings, select the block and use Import, Edit, Advanced or Remove (see The Five Blocks).
Page drawings screen, ready to edit the blocks
Click Next > until the Review screen and check the summary of the changes.
Click Finish.
ARES Electrical saves the changes to the page.
💡TIP: On the Page selection screen, the list is in alphabetical order, with the default pages ([ANSI] and [IEC]) first. The pages you created, such as TREINAMENTO, appear at the end of the list. Use the scroll bar to find them.
📖INFO: The Page selection screen lets you check one or more pages at the same time. Check several pages when you want to apply the same change to all of them, such as changing the sheet format or the title block logo.
📖INFO: On screens where there is nothing to change, simply click Next >. The settings of those screens are kept as they are.
Deleting Pages
Pages that are no longer used can be deleted with the same wizard. You can delete a single page or several at once.
In this example, we will delete the TREINAMENTO page, created earlier.
Open the Page Settings Wizard (Manage tab → Settings → Page Groups…).
On the Page Settings Wizard screen, select Delete one or more pages.
Page Settings Wizard with the Delete one or more pages option selected
Click Next >.
On the Select pages to delete screen, find the page in the Name list and check the box next to it, for example TREINAMENTO.
Select pages to delete screen with the TREINAMENTO page checked
Click Next >.
On the Review screen, check the summary, for example The page TREINAMENTO will be deleted.
Review screen confirming that the TREINAMENTO page will be deleted
Click Finish.
ARES Electrical deletes the selected page, which no longer appears in the wizard’s page list.
💡TIP: To delete several pages at once, check all of them on the Select pages to delete screen. The Review screen shows the complete list of pages that will be deleted.
⚠️WARNING: Check the Review screen carefully before clicking Finish. If you checked a page by mistake, click < Back and uncheck it.
⚠️WARNING: Before deleting a page, make sure it is not used by any Page Group. If in doubt, export the Electrical Settings first, as a backup (see Importing and Exporting the Settings).
Configuring Page Groups
Page Groups organize the project into sections, such as cover, table of contents, power and control schematics, layout and reports (Chapter 1). Each group defines which pages it uses and the properties that are inherited by all pages created in it, such as the name, the order in the project and the numbering.
Groups are created in the same Page Settings Wizard used for pages. In this topic, we will create the TREINAMENTO group and use in it the page created in Configuring the Pages.
Project Languages
An ARES Electrical project can have more than one language. For each language in use, the Page Group has its own settings: the Page selection and Group properties screens show a section for each language, such as English and Português.
The languages in use are defined in the Edit Project Languages window. Define the languages before creating the groups.
On the Ribbon, click the Manage tab.
In the Settings panel, click Edit Project Languages…
Manage tab, with Page Groups… and Edit Project Languages… in the Settings panel
In the Edit Project Languages window, check the languages listed in the Language column.
Edit Project Languages window with English and Português in use
To add a language, click a line, select the language you want, for example German, and check the box in the In Use column.
German language added and checked as In Use
To stop using a language, uncheck the box in the In Use column.
Click Apply and then OK.
ARES Electrical now shows a section for each language in use on the wizard screens.
💡TIP: Command: AECCFGTRADELANG
📖INFO: The project languages are different from the application language and the library language (see Application and Library Language). Those define the language of the interface and of the library. The project languages define in which languages the project itself is documented, such as the names of the Page Groups.
Creating a Page Group
Like the page, a new group can be created in two ways:
Using default values – the group starts with the ARES Electrical default settings.
Copying properties from: – the group starts with the settings of an existing group, chosen from the list. You only need to adjust what is different.
New page group screen with the Using default values and Copying properties from: options
To create the group:
Open the Page Settings Wizard (Manage tab → Settings panel → Page Groups…).
On the Page Settings Wizard screen, select Create a new page group and click Next >.
On the New page group screen, select Copying properties from:.
In the Name list, check the group that will be used as the base, for example TREINAMENTO.
Click Next >.
ARES Electrical moves to the Group properties screen.
📖INFO: With the Copying properties from: option, the Next > button is only enabled after a group is checked in the list.
Group Properties
The Group properties screen defines the properties of the group in each language. Each line has the Property, Value and Help columns:
Name – description of the page group, for example TREINAMENTO. This is the name that appears in the Project Palette and in Insert groups…
Short name – short description of the page group.
Numerical order – position of the group in the project, when the project is set to sort groups by number.
Automatic numbering – when checked, the pages of the group are numbered automatically.
Hidden – when checked, the group is not included in the table of contents or in the page numbering per project.
Total in – defines in which group the page total (OUT_OF) is calculated, for example This group or another group of the project, such as [IEC] CAPA.
Initialize at – number of the first page of the group, for example 1.
To fill in the properties:
In the language section, click the Value column of the Name line and type the group name, for example TREINAMENTO.
If you want, fill in the Short name.
In Numerical order, type the position of the group in the project, for example 4.
Check or uncheck Automatic numbering and Hidden.
In Total in, choose This group or the group in which the total will be calculated.
In Initialize at, type the number of the first page, for example 1.
Repeat for the other languages.
Click Next >.
ARES Electrical saves the group properties in each language.
📖INFO: When a new language is added to the project, such as German, the Group properties screen shows a section for it, with initial values such as Novo grupo in the Name. Fill in the properties of the new language in the same way.
Group properties screen with the German language section added
📖INFO: The properties filled in in the Page Group are inherited by all pages of the group, including those added later (Chapter 1 – Page Group Properties).
Group Page Selection
The Page selection screen defines which pages the group uses. For each language in use in the project, there are three lines:
Cover – page used for the group cover.
Index – page used for the group table of contents.
Default – page used for all other pages of the group, for example [IEC] EN A3 in English and [IEC] PT A3 in Português.
Page Settings Wizard: selection of the page types by language
To choose the pages:
In the language section, click the list in the Value column of the line you want.
Select the page. To use the page created in Configuring the Pages, select TREINAMENTO.
Repeat for the other languages.
Click Next >.
ARES Electrical now creates the group pages with the selected pages.
📖INFO: The Cover and Index lines can be left blank when the group has no cover or table of contents of its own, as in a schematics group. In this case, all pages of the group use the Default page.
Review
The Review screen is the last step of the wizard. It shows a summary of what will be done before any change is saved. For each language in use in the project, the wizard shows a line with the group name and the language, for example:
The group TREINAMENTO will be created in the language English
The group TREINAMENTO will be created in the language Português
The group TREINAMENTO will be created in the language German
On this screen, use the buttons:
< Back – goes back to the previous screens, to correct some information.
Finish – confirms and creates the group.
Cancel – closes the wizard without saving the changes.
To complete the group creation:
On the Review screen, check the group name in each language.
Review screen with the group that will be created in each project language
If you need to correct something, click < Back and adjust the screen you want.
Click Finish.
ARES Electrical creates the new Page Group, which now appears in Insert groups…, in the Project Palette.
📖INFO: When copying properties, the group name starts as Copy of followed by the name of the source group. If the Review screen still shows Copy of… or Novo grupo in any language, click < Back until Group properties and change the name.
Editing a Page Group
A group that was already created can be changed at any time with the same wizard. The screens are the same as for creation (Group properties and Page selection), and you can change the pages used by the group, the name, the order and the numbering in each language.
In this example, we will edit the TREINAMENTO group, created earlier.
On the Ribbon, click the Manage tab and, in the Settings panel, click Page Groups…
On the Page Settings Wizard screen, select Edit an existing page group.
Page Settings Wizard with the Edit an existing page group option selected
Click Next >.
On the Group selection screen, find the group in the Name list and check the box next to it, for example TREINAMENTO.
Group selection screen with the TREINAMENTO group checked
Click Next >.
On the Group properties screen, change the Name, the Numeric order, the numbering or the total in each language, if necessary (see Group Properties).
Group properties screen of the TREINAMENTO group, with the German section still with the initial values
Click Next >.
On the Page selection screen, change the pages used as Cover, Index and Default in each language, if necessary (see Group Page Selection).
Page selection screen of the TREINAMENTO group, with the English, Português and German languages
Click Next > until the Review screen and check the summary of the changes.
Click Finish.
ARES Electrical saves the changes to the group.
💡TIP: On the Group selection screen, the default groups ([ANSI] and [IEC]) appear first. The groups you created, such as TREINAMENTO, appear at the end of the list. Use the scroll bar to find them.
📖INFO: After adding a new language to the project (see Project Languages), edit the existing groups to fill in the section of the new language. In the example, the German section of the TREINAMENTO group still has the name Novo grupo and needs to be filled in.
📖INFO: The Group selection screen lets you check one or more groups at the same time. On screens where there is nothing to change, simply click Next >.
Deleting Page Groups
Groups that are no longer used can be deleted with the same wizard. You can delete a single group or several at once.
In this example, we will delete the TREINAMENTO group, created earlier.
On the Ribbon, click the Manage tab and, in the Settings panel, click Page Groups…
On the Page Settings Wizard screen, select Delete one or more page groups.
Page Settings Wizard with the Delete one or more page groups option selected
Click Next >.
On the Select groups to delete screen, find the group in the Name list and check the box next to it, for example TREINAMENTO.
Select groups to delete screen with the TREINAMENTO group checked
Click Next >.
On the Review screen, check the summary, for example The group TREINAMENTO will be deleted.
Review screen confirming that the TREINAMENTO group will be deleted
Click Finish.
ARES Electrical deletes the selected group, which no longer appears in the wizard’s group list or in Insert groups…
💡TIP: To delete several groups at once, check all of them on the Select groups to delete screen.
⚠️WARNING: Check the Review screen carefully before clicking Finish. If you checked a group by mistake, click < Back and uncheck it.
📖INFO: Deleting a group does not delete the pages configured in the wizard that it used, such as the TREINAMENTO page. To remove them too, use Delete one or more pages (see Deleting Pages).
📖INFO: After creating, changing or deleting Page Groups, export the Electrical Settings. This way, the same standard can be imported into all company projects.
Key Points
The Electrical Settings are opened from the Ribbon (Manage → Electrical Settings…), with the AECFG command or with the OPTIONS command, on the Electrical tab.
The interface language is in Options → System Options → General → Application language, and the library language in Electrical Settings → User → Library → Library Language.
Export the settings to a .cfg file before any change and import it to take the company standard to all projects.
Pages and Page Groups are created, edited and deleted in the Page Settings Wizard (Manage → Settings → Page Groups…).
Copying the properties of an existing page is the fastest way to create a page in the company standard.
Each page is made up of five blocks: Sheet format, Group properties, Page properties, Page number and Page total.
Each Page Group defines the pages it uses and its properties in each project language, defined in Edit Project Languages.
Still have questions?
Feel free to contact our support team at [email protected].